This Residual Current Circuit Breaker is part of Eaton's xEffect industrial range and fulfills the highest requirement of extended air and creeping distances according UL 1053 standard. This protection device completes Eaton's Residual Current Circuit Breaker product range and is particularly suitable for the protection of people and equipment in industrial applications.
Design according to
IEC/EN 61008
Suitable for global use
UL 1053
Rated tripping current
30, 300 mA

Core features

  • Residual current devices
  • The 4-pole device can also be used for 2-pole connection
  • Special type with 110 V also available
  • The RCD is suitable for “fault current/residual current protection” and “additional protection” within the meaning of the applicable installation rules
  • The device functions irrespective of the position of installation
  • Tripping is line voltage-independent
  • Type -A: Protects against special forms of non-smoothed residual pulsating DC
  • Purpose terminal lift above and below
  • Universal tripping signal switch, also suitable for FAZ.
  • FRBmM-1N, auxiliary switch Z-HK can be mounted subsequently
  • Contact position indicator red - green
  • Tripping indicator white - blue
  • All types can be used with standard fluorescent tubes with or without electronical ballast (30mA-RCD: 30 units per phase conductor, 300mA-RCD: 90 units per phase conductor)
  • Type -G/A: Additionally protects against special forms of non-smoothed residual pulsating DC
  • Mains connection at either side

Reliable protection for machines

These products provide optimal system and additional protection against residual earth leakage currents for a wide range of applications. They come with different tripping characteristics to cater for a variety of electrical systems and components. The devices offer a wide range of nominal currents and comprehensive optional accessories.

Suitable for global use

Eaton’s comprehensive range of compact RCCBs for fault current and additional protection meet the requirements of the UL 1053 and IEC/EN 61008 standards, making them suitable for global use.

Different types are available

Type A: Protection against special forms of residual pulsating DC currents that have not been smoothed.

Type G/A: Additional protection against special forms of residual pulsating DC currents that have not been smoothed. High level of protection against nuisance tripping.
Specifications

Highlight differences
Show only differences
Hide blank features
Download Links